JCC Fireguard Plus 5W LED IP65 Fire Rated Showerlight
£58.64 inc VAT
£48.87 exc VAT
The Next Generation of Fire-rated LED Downlights. Exceeds 45 lumens per circuit Watt in accordance with the proposed new England & Wales building regulations (Part L)
'A' rated for energy efficiency
90% energy savings against a 50W halogen equivalent
Integrated 5W (4.7W) LED light source. IntegraI driver. Mains voltage 240V
3000K white, CRI:Ra (80) LED lamp, 35,000 hours average life. 40 degree beam angle.
Fit & forget design to minimise installation costs. Small size ideal for shallow voids
Fire-rated in accordance with England and Wales building regulations part B - Fully tested for 30, 60 & 90 minute ceilings
Acoustic ring maintains the seal around the front of the fitting for compliance with England and Wales building regulations part E (acoustic standards) and part C (moisture protection)
Patented thermo plastic intumescent plug with superior convection 'petal' design and high thermal dynamics
Mind the Gap - extra intumescent material for added reassurance
Available in brushed nickel, chrome or white, please choose.
Recessed Depth: 120mm
- Manufacturer
- JCC Lighting
- Product Code
- JC94171
- Height
- Recessed Depth 020mm
- Width
- 88mm Dia
- Depth
- n/a
- Length/Diam.
- n/a
Table 40: Minimum provisions for fixed internal and external lighting
Lighting. New and replacement systems
Fixed internal lighting
a. In the areas affected by the building work, provide low
energy light fittings (fixed lights or lighting units) that
number not less than three per four of all the light
fittings in the main dwelling spaces of those areas
(excluding infrequently accessed spaces used for storage,
such as cupboards and wardrobes).
a. Low energy light/fittings should have lamps with
a luminous efficacy greater than 45 lamp lumens
per circuit-watt and a total output greater than
400 lamp lumens.
Light fittings whose supplied power is less than 5 circuit-
watts are excluded from the overall count of the total
number of light fittings.
Supplementary information
Light fittings may be either:
a. dedicated fittings which will have separate control
gear and will take only low energy lamps (e .g. pin
based fluorescent or compact fluorescent lamps);
or
b. Standard fittings supplied with low energy lamps
with integrated control gear (e.g. bayonet or
Edison screw base compact fluorescent lamps).
Light fittings with GLS tungsten filament lamps or tungsten
halogen lamps would not meet the standard.
The Energy Saving Trust publication GIL 20, "Low energy
domestic lighting", gives guidance on identifying suitable
locations for fixed energy efficient lighting.
|